1 auto mode.
2 temperature selection / left side.
3 A / C activation.
4 display / right side.
5 air recirculation.
6 heater circuit -> residual.
7 display / left side.
8 ventilation (blower) speed selection.
9 rear window defrost.
10 temperature selection / right side.
11 windscreen defrost.
12 air distribution : 'high' air vent.
13 air distribution : front air vent.
14 air distribution : air vent to the footwell.
BB00 battery.
BPGA/1032 cartridge fuses additional box.
BSI fuses-relays-C. U. entity.
PSF1 fuse and relay box / motor.
0004 dashboard instrument subsystem.
1320 engine control unit - ECU.
6400 outside temperature sensor.
8006 temperature sensor of the evaporator.
8007/8009 A/C refrigerant high pressure HP sensor.
8020 A/C compressor.
8033 sunlight sensor.
8045 cabin blower control module.
8050 cabin blower.
8063 air mix motor / right side.
8064 air mix motor / left side.
8070 air recirculation motor.
8071 air distribution flap servomotor -> central.
8073 air distribution flap servomotor -> feet / defrost.
8080 A/C control unit.
8084 heating resistances of the auxiliary heater.
84C6 A/C control interface.
= = = multiplexed signal CAN.
---> all or nothing 12 v signal.
=== analog linear signal.
- - -> pulsated modulated signal.
The parameters monitoring the A/C system are conveyed by the multiplex network which joins the various control units BSI 1320 8080.
In addition to its electromagnetic clutch 2, the A/C compressor with remote control is equipped with a solenoid valve 1 which manages the low pressure, thus allowing to monitor the evaporator temperature between 3 and 13 °C. It aims to produce the amount of cold neceessary to be comfortable and, this way, save fuel.
When the A/C compressor is not engaged, the solenoid valve of the compressor delivers at 0 %.
.
* ambient temperature 20° C.
.
To achieve an A/C evaporator temperature of 3 °C.
-> the control signal of the compressor solenoid valve reachs roughly 50 %.
To achieve an A/C evaporator temperature of 10 °C.
-> the control signal of the compressor solenoid valve reachs roughly 35 %.
The HP shut-off thresholds and the restart thresholds - level of engine revs permitting - are ->.
The thresholds for cut-off (low pressure) and restart, linked to engine speed conditions, are ->.
Under 3,5 °C outside temperature, the A/C compressor is shut off.
Defects which trigger the A/C compressor cut-off.
A fault on the evaporator sensor does not trigger the shut off of the compressor, but a fixed pulsated value of the A/C compressor solenoid valve in relation to the outside temperature.
Modulated signal : 62 % at 20 °C.
Modulated signal : 66 % at 30 °C.
Modulated signal : 71 % at 40 °C.
Modulated signal : 76 % at 50 °C.
The A/C drives the speed of the motorfan to properly cool the condensator.
This request changes according to the pressure level of the gas coolant circuit.
The motor-fan speed is adapted by a two-speed relay.
BB00 battery.
BSI1 fuses-relays-C. U. entity.
BRFM / PSF1 fuse and relay box / motor.
1220 motor temperature sensor.
1320 engine control unit - ECU.
1510 motoventilator of the A/C condenser.
1522 two-speeds relay.
1380 thermostat of the engine coolant **.
70--/78-- bridge / ESC - electronic stability control *.
8007 A/C refrigerant high pressure HP sensor.
---> wired connection.
= = = multiplexed signal.
===> analog linear signal.
1 signal of the pressure sensor.
2 information low speed motoventilator of the engine coolant circuit.
3 information high speed motoventilator of the engine coolant circuit.
4 power relais of the + with ignition ON.
5 power supply voltage motoventilator of the engine coolant circuit.
6 power supply voltage.
7 temperature signal of the motor.
8 multiplexed signal.
.
* bridge -> ESC - electronic stability control.
** according to the motor.